Selecting a Furnace|

The lightweight, versatile 200 single pass heater is designed with a lifetime limited heat exchanger warranty and an advanced heat exchange. This heat exchange reduces thermal stress points, which creates a longer life span and allows for easier maintenance. - Heat exchanger design eliminates the need and cost of a burner target
- Tubeless: No fuel tubes means reduced cleaning time, no tube replacement or repair costs
- Accessible Design: Labor saving with up to 75% less cleaning time than a conventional multi-pass system
- Warranty: lifetime limited heat exchanger warranty
- Versatile: Dual stack connections vent gas out left or right side for more versatile installation. Model 200 also provides multi-directional air ventilation through the left and/or right side and up or down louvering.
- Squirrel Cage Blower Standard
- Multiple Voltages: 120-volt/60-amp and 220-volt/50-amp available
- Multiple Mounting: Designed for floor stand, tank rack or ceiling suspension mounting
- Customized regular and complete maintenance of heat exchanger.
| | Input (approx. BTU/hr.) | 200,000 | | Output (approx. BTU/hr.) | 160,000 | | Stack size | 8" | | Shipping Weight | 437 lbs./199 kg. | Heater dimensions (L x W x H) Includes outside measurements of fan and burner | 34.5" x 22" x 92.5" | | Duct Opening | 16" x 16" | | Electrical requirements (maximum circuit protection) | 30A (15A for export) | | Approx. fuel consumption | 1.43 GPH | | Blower CFM | 2550 | | Outlet Air Temperature | 170 F | | Compressed air requirements | 2 CFM @ 40 PSI | | Agency listings | UL, C-UL | | Patents | 5,950,616 | | Fuels | Crankcase oil, transmission and hydraulic fluids, as well as other petroleum-based lubricants (any weight combinations up to SAE 50 as well as #1 and #2 fuel oil.) | | Oil transfer pump | 18 GPH @ 35 PSI (68 LPH @ .24 Mpa) | |
The Horizon 245 single pass heater is the perfect design for any shop. The multiple mounting systems allow for floor stand, tank rack or ceiling suspension mounting. Thanks to the accessible swinging door design near the chamber, up to 75% cleaning time is saved when compared to a conventional multi-pass system.
- Efficiency: The innovative Horizon Heater's heat exchanger design eliminates the costs of a burner target. This system also contains no fuel tubes, which means reduced cleaning time and no tube repair costs.
- Advanced Heat Exchanger Design: Reduces corners and thermal stress points to provide longer life and easier upkeep
- Warranty: lifetime limited heat exchanger warranty
- Dual Stack Connections: Vent gas out left or right side for a more versatile installation
- Dual, Multi-Directional Air Outlets: Left and/or right side, up or down, right or left louvering
- Squirrel Cage Blower Standard
- Light Weight: Easy to handle and install
- Multiple Voltages: 120-volt/60-amp and 220-volt/50-amp available
- Customized Heat Exchanger Cleanout Tool Standard: Promotes regular and complete maintenance of heat exchanger
| | Input (approx. BTU/hr.) | 245,000 | | Output (approx. BTU/hr.) | 188,000 | | Stack size | 8" / 20.3 cm | | Shipping Weight | 500 lbs./227 kg. | Heater dimensions (L x W x H) Includes outside measurements of fan and burner | 41" x 26" x 99.5" | | Duct Opening | 18" x 18" | | Electrical requirements (maximum circuit protection) | 30A (15A for export) | | Approx. fuel consumption | 1.73 GPH | | Blower CFM | 2780 | | Outlet Air Temperature | 180 F | | Compressed air requirements | 2 CFM @ 40 PSI / .057 m3/min.@.28Mpa | | Agency listings | UL, C-UL | | Patents | 5,950,616 | | Fuels | Crankcase oil, transmission and hydraulic fluids, as well as other petroleum-based lubricants (any weight combinations up to SAE 50 as well as #1 and #2 fuel oil.) | | Oil transfer pump | 18 GPH @ 35 PSI (68 LPH @ .24 Mpa) | |

The Horizon 315 single pass heater is the perfect design for any shop. The multiple mounting systems allow for floor stand, tank rack or ceiling suspension mounting. Thanks to the accessible swinging door design near the chamber, up to 75% cleaning time is saved when compared to a conventional multi-pass system. - Efficiency: The innovative Horizon Heater's heat exchanger design eliminates the costs of a burner target. This system also contains no fuel tubes, which means reduced cleaning time and no tube repair costs.
- Advanced Heat Exchanger Design: Reduces corners and thermal stress points to provide longer life and easier upkeep
- Warranty: lifetime limited heat exchanger warranty
- Dual Stack Connections: Vent gas out left or right side for a more versatile installation
- Dual, Multi-Directional Air Outlets: Left and/or right side, up or down, right or left louvering
- Squirrel Cage Blower Standard
- Light Weight: Easy to handle and install
- Multiple Voltages: 120-volt/60-amp and 220-volt/50-amp available
- Customized Heat Exchanger Cleanout Tool Standard: Promotes regular and complete maintenance of heat exchanger
| | Input (approx. BTU/hr.) | 315,000 | | Output (approx. BTU/hr.) | 252,000 | | Stack size | 8" / 20.3 cm | | Shipping Weight | 569 lbs./259 kg. | Heater dimensions (L x W x H) Includes outside measurements of fan and burner | 41" x 26" x 113.5" | | Duct Opening | 18" x 18" | | Electrical requirements (maximum circuit protection) | 30A (15A for export) | | Approx. fuel consumption | 2.25 GPH | | Blower CFM | 2780 | | Outlet Air Temperature | 180 F | | Compressed air requirements | 2 CFM @ 40 PSI / .057 m3/min.@.28Mpa | | Agency listings | UL, C-UL | | Patents | 5,950,616 | | Fuels | Crankcase oil, transmission and hydraulic fluids, as well as other petroleum-based lubricants (any weight combinations up to SAE 50 as well as #1 and #2 fuel oil.) | | Oil transfer pump | 18 GPH @ 35 PSI (68 LPH @ .24 Mpa) | |

- Easy to Maintain: Firelake's three-pass heater models are easy to maintain with clean-out panels on both ends of the heat exchanger
- Durability: Designed for a maximum heat transfer with 100% steel corrosion resistant fire chamber and heat exchanger
| | Input (approx. BTU/hr.) | 500,000 (126,000 Kcal) | | Output (approx. BTU/hr.) | 400,000 (100,800 Kcal) | | Stack size | 10" ( 25.4 cm ) | | Shipping Weight | 927lbs. (421 kg.) | Heater dimensions (L x W x H) Includes outside measurements of fan and burner | 52.31" x 69.5" x 34" (132 x 177 x 86 cm) | | Electrical requirements (maximum circuit protection) | 220 vac ,30 amp | | Approx. fuel consumption | 3.6 GPH (13.63 liter/hour) | | Blower CFM | 5800 (164 cubic meter/minute) | | Outlet Air Temperature | 170 F (77 C) | | Compressed air requirements | 2 CFM @ 40 PSI / .057 m3/min.@.28Mpa | Agency listings Patents | UL, C-UL 5,950,616 | | Fuels | Crankcase oil, transmission and hydraulic fluids, as well as other petroleum-based lubricants (any weight combinations up to SAE 50 as well as #1 and #2 fuel oil.) fuel oil.) | | Oil transfer pump | 18 GPH @ 35 PSI (68 LPH @ .24 Mpa) | |
|